The uploaded files must have names from which the expected content can be derived, e.a. they need to have correct file extensions. The casing of file extensions does not matter, in this table they are all uppercase.
The currently supported file extensions are:
| Extension | File type | Description |
|---|---|---|
| IFC | Industry Foundation Classes, can be IFC2X3, IFC4 or IFC4X3 | The actual schema that is used is stored in the IFC header within the file, so the extension is always .IFC |
| IFCZIP | Same as above, but zipped. Can and must only contain one file, and that needs to be a regular IFC file. For more information: https://standards.buildingsmart.org/documents/Implementation/IFC_Implementation_Agreements/CV-2x3-154.html | The content will be extracted directly into a MODEL node. In other words no additional FOLDER node will be created. |
| ZIP | Can contain a folder hyrarchy and can contain both IFCZIP and IFC file. | The content fill be extracted in BIM.works using FOLDER nodes. Only the actual models are created as MODEL nodes. |
| E57 | PointCloud format. Currently only a very basic X, Y, Z + color is supported. |
BIM.works validates the IFC models and tries to help the user to solve common issues by returning useful error messages as much as possible. Error messages in BIM.works are organized into groups/namespaces. When uploading a model you can expect error messages coming from different namespaces.
The StepParserErrorCode messages indicate errors while parsing the IFC file. They generally include a line number and position (on the line) to help with identifying the issue. Most implementations should not show these errors to the end user, but log the errors in a log file. The rows with a yellow background indicate the most common errors.
| Value | Code | Description |
|---|---|---|
UNEXPECTED_CHARACTER |
0 | An unexpected character was encountered |
NO_SEMICOLON_FOUND_IN_RECORD |
2 | A record did not end with a semicolon |
NO_LEFT_PARENTHESIS_FOUND_IN_RECORD |
3 | Left parenthesis are missing |
NO_RIGHT_PARENTHESIS_FOUND_IN_RECORD |
4 | Right parenthesis are missing |
STRING_ENCODING_X2_NOT_CLOSED_WITH_X0 |
6 | X2 string encoding was nog closed with an X0 |
STRING_ENCODING_NUMBER_OF_HEX_CHARS_IN_X2_NOT_DIVISIBLE_BY_4 |
7 | The amount of hex chars is not divisible by 4, which is a requirement |
STRING_ENCODING_CHARACTER_DECODING_EXCEPTION |
8 | A general string decoding error happened, more details in the user message. |
STRING_ENCODING_X4_NOT_CLOSED_WITH_X0 |
9 | X4 string encoding was nog closed with an X0 |
STRING_ENCODING_NUMBER_OF_HEX_CHARS_IN_X4_NOT_DIVISIBLE_BY_8 |
10 | The amount of hex chars is not divisible by 8, which is a requirement |
STRING_ENCODING_UTF32_NOT_SUPPORTED_ON_SYSTEM |
11 | UTF32 should always be supported, so this error should never be thrown, if it is, please let us know. |
EXPECTED_STRING |
12 | A String value was expected, but something else was found |
INVALID_DATETIME_LITERAL |
13 | The datetime literal is invalid. BIM.works has been made slightly more lenient than the spec here, so it does not always throw this exception on invalid datetime. |
INTERNAL_ERROR |
16 | An internal error happened in the IFC parser. Please always report this error as it’s most certainly an implementation error. |
EXPECTED_LIST |
17 | A list was expected but something else was found, details in the user message |
INSUFFICIENT_BUFFER_SIZE |
18 | Insufficient buffer size, this is an internal error and should never happen. |
INVALID_REFERENCE |
20 | This is a relatively common error. It means that a reference was made to an entity that does not exist in the IFC model. BIM.works is relatively strict on this, some other implementation will try to continue reading the IFC model. |
INVALID_DOUBLE_LITERAL |
21 | An invalid double literal was encountered |
UNKNOWN_ENTITY_TYPE |
23 | This is also a relatively common error. This will happen whenever an IFC entity name was used that does not exist in any of the supported schemas. |
CANNOT_READ_AHEAD |
24 | This is an internal error and should be reported |
INVALID_LONG_LITERAL |
25 | An invalid long literal was encountered |
INVALID_EXPRESS_ID |
26 | An invalid express id was encountered. Examples of invalid express id: Zero or a negative value |
EQUALS_EXPECTED |
27 | An equals sign was expected but something else found |
UNKNOWN_SCHEMA |
28 | An unknown/invalid IFC schema was provided |
EMPTY_ENTITY |
29 | An empty entity was provided, which is not valid |
UNEXPECTED_ZIP_FILE |
30 | It seems as if zip content was provided where IFC content was expected |
NO_IFC |
31 | Something other than IFC was found |
These are more generic BIM.works error codes, also used for other API calls.
| Value | Code | Description |
|---|---|---|
PARENT_NODE_NOT_FOUND |
14 | The subject Node is referring to a parent node that does not exist (anymore) |
NODE_ALREADY_EXISTS |
19 | A Node with the given name already exists at this path |
DIFFERENT_FILENAME |
25 | A model is being uploaded with a filename to a Node that has a different name. This error is only thrown when the user has not specified NEW_VERSION nor NEW_MODEL as an option to the upload. |
NO_HASH_IN_REQUEST |
26 | A hash of the model was expected to be in the request but it was not |
MODEL_IDENTIFIER_VALIDATION_EXCEPTION |
31 | An error occured during model identifier validation, usually this means that non-existing or invalid version UUID were included. |
INVITE_EXPIRED |
40 | The invite has expired |
INVITE_ALREADY_ACCEPTED |
41 | Invite was already accepted |
NODE_NOT_FOUND |
93 | The requested Node was not found, can be because of deletion, authorization changes, incorrect UUIDs |
NO_DEMO_NODE |
42 | The user has no “Demo” Node |
EXPECTED_EXACTLY_ONE_MODEL |
43 | This part of the application expected there to be exactly one model, but the user provided multiple |
MODEL_NOT_FOUND |
44 | A particular model was not found. This is mostly an internal message and usually indicates something is wrong on the server |